Appendix E Diagnostic Hardware Program This manual describes the troubleshooting procedure that applies the check program for the E8 emulator. System Setup to Execute the Check Program (1) The following equipments are required to execute the check program. Do not connect the user system interface cable or the user system while the check program is running.Renesas E1/e20 Self Check ProgramsThe E1/E20 manual consists of multiple parts: the E1/E20 Emulator User's Manual and the additional documents for the user's manual for each MCU.
![]()
E1/E20 Self Check にて 「TEST2: Loop back check」段階で 「The E1/E20 self-check has failed.」となります。 TEST1とTEST2はケーブルをE1本体のself checkコネクタに接続する必要がありますが、その点間違いないでしょうか? 手順があってるならケーブルが切れてるか、本体の. System configuration (Programming with Renesas Flash Progarammer V3) Refer to the image of the connection with the E1 emulator, below. Note: When using with the on-chip debugging emulators, conversion adapter is required depending on the number of pins on the target board.
Be sure to read each part before using the E1/E20 emulator. In reply to FrankL. Hi FrankL, Thank you for your reply.
Previously I changed the inline resistor RA7 so the emulator work perfectly only for 1 day. After that it is not worked.
E8 emulator station. USB cable included with the E8 emulator. CD included with the E8 emulator. Host computer (hareafter, PC) Install the High-performance Embedded Workshop and USB driver on the PC in advance. (2) Start up the host computer, and connect the E8 emulator to the USB connector of the host computer via the USB cable attached. Prior to this, the user interface cable must be disconnected. Executing the Check Program (1) Execute Program-Renesas-High-performance Embedded Workshop-E8 Self Check Program.Figure E.1 Starting Up the Check Program 143.Read E8aSCP (E8a Self-Check Program) text version E8aSCP (E8a Self-Check Program) This document describes the troubleshooting procedure that applies the self-check program for the E8a emulator (E8aSCP).
![]() ![]()
System Setup to Execute the E8aSCP (1) The following equipment is required to execute the check program. Do not connect the user system interface cable or the user system while the check program is running.E8a emulator main unit USB cable included with the E8a emulator User system interface cable included with the E8a emulator CD included with the E8a emulator Host computer Install the High-performance Embedded Workshop and the USB driver on the host computer in advance. (2) Open the cover of the self-check connector for the emulator. Connect the user system interface cable to the user-system connector and the self-check connector.
Fully insert the user system interface cable in the self-check connector as shown in figure 2. Figure 1 Connecting the User System Interface Cable when Using the E8aSCP Figure 2 Connecting the User System Interface Cable to the Self-Check Connector (3) Start up the host computer, and connect the E8a emulator to the USB connector of the host computer via the USB cable provided. X photoshop download. Executing the Self-Check Program (1) Execute Program-Renesas-High-performance Embedded Workshop-E8a Self Check Program.Figure 3 Starting Up the E8aSCP (2) Click the `START' button. The following message will be displayed: `Please confirm that the User interface cable is connected to the self-check connector in a correct direction'.Confirm that the user system interface cable is connected to the self-check connector in the correct direction, as shown in figure E.2, and click the OK button. The self-check program will start. Figure 4 Confirming Connection of the User System Interface Cable (3) The message `TEST1 is running.'
Or `TEST2 is running.' Will appear in the window.
This indicates the start of the self-check program.cokecd.